DRC-12V30W1AZ
Output Voltage: 12V
Output Power: 25W
Output Current: 2.1A
Input Voltage Range: 90-264Vac
Dimensions (H x W x D): 91 x 53 x 55.6 mm
Unit Weight: 0.14 kg (0.31 lb)
Highlights & Features
- Class II, Double Isolation (No Earth connection is required)
- Universal AC input voltage range and full power up to 55°C
- Power will not de-rate for the entire input voltage range
- Efficiency > 85.0% @ 115Vac & 230Vac
- Can be installed in compact cabinets
- NEC Class 2 and Limited Power Source (LPS) approvals
- Conforms to harmonic current IEC/EN 61000-3-2, Class A
- Safety approval according to IEC/EN/UL 60950-1, IEC/EN/UL 62368-1 and UL508
Output Current: 2.1A |
Output Voltage: 12V |
Output Voltage Adjustment Range: 11.5-14.5Vdc |
Output Power: 25W |
Line Regulation: < 0.5% (@ 90-264Vac input, 100% load) |
Load Regulation: < 1.0% (@ 90-264Vac input, 0-100% load) |
PARD: < 100mVpp |
Start-up Time: < 2,000ms @ nominal input (100% load) |
Hold-up Time: > 25ms @ 115Vac, > 60ms @ 230Vac (100% load) |
Dynamic Response (Overshoot & Undershoot O/P Voltage): ± 5% @ 90-264Vac input, 10-100% load (Slew Rate: 0.1A/μs, 50% duty cycle @ 5Hz to 100Hz) |
Start-up with Capacitive Loads: 3,000µF Max |
Rise Time: < 70ms @ nominal input (100% load) |
Nominal Input Voltage: 100-240Vac |
Input Voltage Range: 90-264Vac |
Nominal Input Frequency: 50-60Hz |
Input Frequency Range: 47-63Hz |
DC Input Voltage Range: 125-375Vdc |
Input Current: < 0.80A @ 115Vac, < 0.60A @ 230Vac |
Efficiency at 100% load: > 85.0% @ 115Vac & 230Vac |
Inrush Current: < 25A @ 115Vac, < 50A @ 230Vac |
Leakage Current: < 0.25mA @ 240Vac |
Power Dissipation: 0% load: < 0.3W @ 115Vac & 230Vac, 100% load: < 4.4W @ 115Vac & 230Vac |
Case Chassis / Cover: Plastic |
|
Indicator: Green LED (DC OK) |
|
Cooling System: Convection |
|
Input Terminal: 2 Pins (Rated 300V/25A) |
|
Output Terminal: 4 Pins (Rated 300V/25A) |
|
Noise Sound Pressure Level (SPL): < 25dBA |
|
Mounting Rail: Standard TS35 DIN Rail in accordance with EN 60715 |
|
Wire: Input / Output: AWG 22-12 |
|
Unit Weight: 0.14 kg (0.31 lb) |
|
Dimensions: 91 x 53 x 55.6 mm
Vibration (Operating) : IEC 60068-2-6, Sine Wave: 10-500Hz @ 19.6m/S² (2G peak); |
Shock Test (Operating): IEC 60068-2-27, Half Sine Wave: 4G for a duration of 22ms, |
Operating Temperature: -25°C to +71°C |
Storage Temperature: -25°C to +85°C |
Power De-rating: > 55°C de-rate power by 2.5% / °C |
Operating Humidity: 5 to 95% RH (Non-Condensing) |
Operating Altitude: 0 to 2,000 Meters (6,560 ft.) |
Pollution Degree: 2 |
Over Voltage Category: II |
Overvoltage: < 17.4V, SELV Output, Latch Mode |
Overload / Overcurrent: > 130% of rated load current, Hiccup Mode, Non-Latching (Auto-Recovery) |
Over Temperature: > 75°C Surrounding Air Temperature @ 100% load, Latch Mode |
Short Circuit: Hiccup Mode, Non-Latching (Auto-Recovery when the fault is removed) |
Degree of Protection: IP20 |
Protection Against Shock: Class II (No Primary Earth connection is required) |
Electrical Safety: TUV Bauart: EN 60950-1, EN 62368-1 |
CE: In conformance with EMC Directive 2014/30/EU and Low Voltage Directive 2014/35/EU |
Galvanic Isolation: Input to Output: 3.0KVac |
Industrial Control Equipment: UL/cUL listed: UL 508 and CSA C22.2 No. 107.1-01 (File No. E338991) |
Safety Entry Low Voltage: SELV (EN 60950) |
UKCA: In conformance with 2016 No. 1101. The Electrical Equipment (Safety) Regulations 2016 and 2016 No. 1091 The Electromagnetic Compatibility Regulations 2016 |